BS 5950: Part 4 currently recommends that anticrack mesh should comprise 0.1% of slab area. The Eurocode 4 recommendation is that anticrack mesh should comprise 0.2% of slab area for unpropped spans and 0.4% of slab area for propped spans. The mesh shown in the quick reference tables complies with EC4 and the design program defaults to these values. Where EC4 mesh rules are used, the mesh may be reduced midspan. The reduced British Standard mesh values may still be used by overriding this default in the design program.

Where forklift truck (or other similar concentrated loading) is expected 0.5% minimum percentage reinforcement should be used over the supports and 2% elsewhere to control cracking. For further information refer to the ComFlor® manual.

Mesh top cover must be a minimum of 15mm, and a maximum of 30mm. Mesh laps are to be 300mm for A142 mesh and 400mm for A193, A252 & A393 mesh.

 