Skip navigation

Bi-Steel

Connections

A range of connection methods can be used to join Bi-Steel panels depending on the speed of construction and strength of connection required.

For more information on the friction only connections visit the Surefast pages for details on the 'slot and lock' connection system.

Description  Typical
strength
T/m  

Welding 
 
Intermitent welds, 5mm, size 50/300 30.0
Full strength, 8mm plate, Fy = 355 MPa 520.0
Bolting
(using splice plates)
M16 black bolts, 300 centres, single splice plate 40.0

M20 HSFG's, 150 centres, double splice plate

194.0

Re-bar
inside panel
12mm diameter, each face at 300 centres 27.0

16mm diameter, each face at 150 centres

97.0

Surefast
('slot and lock' connection)
Surefast bolts, 400mm centres, 2T force per bolt 4.0

Surefast bolts, 200mm centres, 4T force per bolt

16.0

It is possible to use a combination of systems to suit a specific requirement.

     